renesas,pwm-rcar.txt 956 B

123456789101112131415161718192021222324252627
  1. * Renesas R-Car PWM Timer Controller
  2. Required Properties:
  3. - compatible: should be "renesas,pwm-rcar" and one of the following.
  4. - "renesas,pwm-r8a7778": for R-Car M1A
  5. - "renesas,pwm-r8a7779": for R-Car H1
  6. - "renesas,pwm-r8a7790": for R-Car H2
  7. - "renesas,pwm-r8a7791": for R-Car M2-W
  8. - "renesas,pwm-r8a7794": for R-Car E2
  9. - "renesas,pwm-r8a7795": for R-Car H3
  10. - reg: base address and length of the registers block for the PWM.
  11. - #pwm-cells: should be 2. See pwm.txt in this directory for a description of
  12. the cells format.
  13. - clocks: clock phandle and specifier pair.
  14. - pinctrl-0: phandle, referring to a default pin configuration node.
  15. - pinctrl-names: Set to "default".
  16. Example: R8A7790 (R-Car H2) PWM Timer node
  17. pwm0: pwm@e6e30000 {
  18. compatible = "renesas,pwm-r8a7790", "renesas,pwm-rcar";
  19. reg = <0 0xe6e30000 0 0x8>;
  20. #pwm-cells = <2>;
  21. clocks = <&mstp5_clks R8A7790_CLK_PWM>;
  22. pinctrl-0 = <&pwm0_pins>;
  23. pinctrl-names = "default";
  24. };