1234567891011121314151617181920212223242526272829303132333435363738 |
- Regulator cooling device.
- The regulator cooling device, will be used to place a voltage floor
- restriction on a rail.
- Properties:
- - compatible:
- Usage: required
- Value type: <string>
- Definition: shall be "qcom,regulator-cooling-device"
- - cdev-supply:
- Usage: required
- Value type: <phandle>
- Definition: phandle to the regulator to which the cooling device will
- place a floor mitigation.
- - regulator-levels:
- Usage: required
- Value type: <U32 array>
- Definition: Array of regulator voltages the cooling device should
- use to place a floor restriction. The voltages should
- be specified in descending order.
- - #cooling-cells: Must be 2. Please refer to
- <devicetree/bindings/thermal/thermal.txt> for more
- details.
- Example:
- mv_cdev: mx-cdev-lvl {
- compatible = "qcom,regulator-cooling-device";
- cdev-supply = <®ulator-cdev-supply>;
- regulator-levels = <RPMH_REGULATOR_LEVEL_NOM
- RPMH_REGULATOR_LEVEL_OFF>;
- #cooling-cells = <2>;
- };
|